Welcome to All Deer Ridge Owners

Welcome to all owners of Deer Ridge Mountain Resort condos in Gatlinburg, Tennessee.

My goal is to help all Deer Ridge owners to have a voice in the management and operation of your property.

Click on the TITLES of any of the following subjects to read the whole posting - and see the comments made by your co-owners. You can also type any term into the below search box, or any word or term in the search cloud.

Click the big image at the top of the page to return to the front page at any time.

Investment Analysis For A Rental Condo At Deer Ridge


Will you really lose $40,000 cash if you buy a rental condo at Deer Ridge and use Ridge Management Ltd?

Click To Download!

As an owner-occupied home, Deer Ridge is an incredible value with THE best view in the Smokies and great amenities.

However, several owners and would-be owners of Deer Ridge condos have asked me if these units are a good rental property investment or not. To help answer that question objectively, I had to analyze the real moving parts of buying and owning here.

Get my complete, detailed investment analysis based on buying a rental condo unit at Deer Ridge Mountain Resort in Gatlinburg, Tennessee.

It shows what you MUST do to make money when you buy a rental unit at Deer Ridge.

Just click the picture or click Investment Analysis

Gross Negligence – Or Is It Fraud?

Legalese On

GENERAL DISCLAIMER FOR ALL PAGES AND POSTS

Note: The following, and the information on any and all other posts and pages by me about General Manager Joe Thomas, GGRC, RML and /or the Board of Directors and its members, or any related topics, are my personal opinions based on my ongoing investigation into the actions and inactions of the GGRC and RML Board of Directors and / or Joe Thomas, General Manager.

While I believe these allegations to be true based on my objective analysis, these opinions remain as only allegations until I, or others, prove things in court.

My goal is to offer all owners all the information and evidence that I have available so that everyone can reach their own conclusions.

Legalese - And Powered Wig - Off

----------------------------

Every Dollar You Pay For Deer Ridge Is The WRONG Amount!

Please read the various posts here on this Deer Ridge Owners Blog - and see my evidence and analysis which I believe shows conclusively that EVERY dollar of HOA Fees, EVERY dollar EVERY special assessment, EVERY water bill and cable TV sent out for YEARS to ALL Deer Ridge Owners has been wrong!

In many cases at least ONE THIRD of ALL owners have been GROSSLY overcharged. My calculations show that I have been overcharged more than TEN THOUSAND DOLLARS in the past 50 months I've owned at Deer Ridge.

The Board has been WRONGLY and arbitrarily ignoring the requirements of the Master Deed and the Bylaws for YEARS.

If my analysis is correct, the Board has zero choice. They MUST abide by the Master Deed Percentages.

But they haven’t.

However, if the Board knowingly ignored the clear directives of the Master Deed and the Bylaws when allocating costs to various unit types, and overcharging certain unit types on a regular basis, my opinion is that the Board and Joe Thomas may have acted fraudulently.

If they have not been fraudulent, then they have been, at the very least, grossly negligent.

Read the various blog postings - and judge for yourself.

Please Register To Log In And Leave Your Comments

Please register first - so you can participate in the discussions by making comments that reflect YOUR opinion.

When you register, please include your unit number so we can confirm you are really an owner!

You are welcome to submit as many comments as you want on any of the topics - or even on a new topic. This is the time and the place to finally have YOUR voice heard with regard to your investment at Deer Ridge Mountain Resort.

I would ask that you include your Deer Ridge unit number at the end of each of your posts so other owners get to know you - however, it is not required. I understand some owners may want anonymity for a variety of reasons - but I will need you to show me that you are an owner.

I may post non-owner comments from time to time if I believe they add to the discussion. When this happens I will note that it is a non-owner comment.

Bear in mind, any and all comments you make here can be seen by all one billion folks on the Internet, worldwide!

Thanks!

"We do not believe any group of men adequate enough or wise enough to operate without scrutiny or without criticism. We know that the only way to avoid error is to detect it, that the only way to detect it is to be free to inquire. We know that in secrecy error undetected will flourish and subvert." — J. Robert Oppenheimer. This includes the Board of Directors of Deer Ridge Mountain Resort.


Inspection Report - Building A and E - Another Failure By Joe Thomas At Deer Ridge

***  Updated Post – Now With Photos By Inspector ***

The following is an inspection report dated November 9, 2009 that was ordered and paid for by Todd Novak, one of the permanent residents and owners here at Deer Ridge.

Todd has been very concerned about the deplorable repairs that were completed by Joe Thomas‘ chosen contractors.  Read the report  yourself – and see if you agree with us that this is yet more evidence of the grossly negligent job performance of Employee and General Manager Joe Thomas.

Does Deer Ridge REALLY need to keep paying $100,000 PLUS per year to this employee?  Isn’t it past time for the Board to FIRE Joe Thomas?  Read the following and see for yourself:

CODE COMPLIANT INSPECTION SERVICES

1193 C H Rankin Road
White Pine Tennessee, 37890
239-470-5753
State Certification # 899
ICC # 8012961-81
ICC # 8012961-82
Project: Deer Ridge Condominiums
Contact: Todd Novak
Buildings Inspected: 3710 A & E Weber Road
Phone: 865-640-8751
Date Of Inspection: November 09, 2009

I was contacted by Todd Novak, 3710 A -304 Weber Road, Gatlinburg, Tennessee, 37738 and asked to inspect the recently constructed exterior staircases, stairs, landings hand railing and supporting members. Mr. Novak expressed concern that the recent construction does not meet the minimum State of Tennessee code adopted standards as enacted by the State Legislators and adopted July 01, 2008.

Those standards being the 2006 International Building Codes for residential buildings over two families and all commercial buildings. This includes not only new construction but all remodeling as well as repairs. Below is a list of areas inspected and related code/construction violations.

1) Stair hand railing was not to correct size. The circumference exceed the code
required size of 2 ” maximum for a round hand rail or minimum 4″ and a maximum 6 1/4 circumference for a non round hand rail. The height of the hand railing varied in height from 29″ to 33″. Code required height is 34″ to 38″ measured from the stair leading edge. Stair guard railing height also varied from 39″ to 41″ and did not meet the code required height of 42″. The hardware used to attach the hand railing was that of interior residential grade hardware and severely corroded. See photos # 001, 005, and 016.

(Note: Please click thumbnail of any photo to get the BIG picture!)

2) Some of the floor and deck joist are not attached to girders, as code requires. They are “toe nailed” to the face of the girders. Code requires the joist to attach to a girder by either bearing on the top chord of the girder, hung with metal joist hangers or bearing on a ledger attached to the face of the girder. Some of the joists were pulling away from the girder with day light showing. In other words the nails were pulling out. Some of the joists were heavily notched. Code requires joist to be blocked over bearing partitions. Many of the joists were not blocked. See photos # 002, 003, 008, 009, 012, 014, 015, 017, and 020.

3) Floor girders in many locations were not supported as code required. Code requires girders to be supported by one of three methods. To bear on a vertical post or column, bear directly on a beam, wall, etc. or attach to a vertical member with a metal hanger. In some cases two girders coming from opposite directions were butted together and nailed. This is extremely concerning because girders are for supporting and carrying concentrated loads. In thjs case those loads are not only from the floor joist on that level but loads from above, bearing down. Girders are also code required to be positively connected to it’s bearing member. This is so the girder supporting the concentrated loads does not vibrate or slide off the bearing member from movement of use or seismic activity. See photos # 007,010,011,018,019,021, and 023.

4) Stair stringers must have full heel bearing on supporting: members (beams) and be attached same as joist. In at least one case the stair stringers were bearing on an unsupported header beam that had another girder attaching to it and not vertically supported. Stair threads were not to code. Stair threads with solid risers are to be a minimum of ten inches with a nosing. The measurement is taken from the leading edge of the thread above at right angle vertically to the thread below. See photos # 004, 013, 023, and 024.

5) Bolts and washers were showing surface rust on some. Suggest they be cleaned and sealed (re-painted) to stop the further spread of rust. No need to replace. See photos 018, 019.

6) Electric side lights were corroded and not sealed for water intrusion. Suggest they be corrected. A electrical cable (UF Romex) was observed exposed and showing at floor joist area. Code requires all exterior electrical feeders to be encased in a protective pipe. Conduit. This is a potential fire or shock hazard. The side light fixture gapping allows rain and like elements to enter causing a potential shock or fire hazard. Suggest they be sealed weather tight. See photos # 006,022,

7} Exterior covering. Fasteners (nails, screws) showing rust. Very obvious. Code requires exterior fasteners to be of corrosion resistance type. Suggest they be replaced.

This inspection was conducted on buildings A &E located at 3710 Weber Road and is limited to these two buildings only and the front stair cases and floor/decking.

Daniel Gabriel
Certified Building Inspector

Instead of Joey having our maintenance staff busy with taking care of off premises cabins, MAYBE he should be attending to the maintenance of Deer Ridge Mountain Resort.

Likewise, maybe Joey should get off his ass and out of his office and actually INSPECT the property and take care of all the massive amount of accumulated deferred maintenance that is obvious everywhere you look.

We have a very capable maintenance person with Tom who could take care of most all of this deferred maintenance at very little cost – if he were properly managed by a competent manager.

It is PAST time for Deer Ridge to FIRE Joe Thomas.  We can’t afford to pay him his $100,000 PLUS compensation even if he was performing.  With his BAD performance, this employee is REALLY a total waste of money for all owners of Deer Ridge.

Tags: inspection report, maintenance, Joe Thomas, Fire Joe Thomas, bad management

1 comment to Inspection Report – Building A and E – Another Failure By Joe Thomas At Deer Ridge

  • Tinamarie Wood

    Todd,

    Thank You VERY MUCH.

    My opinon:

    Not one of us owners wishes for anyone, worker/resident/guest/owner/child injured or killed on our property. Who wants or accepts that liability? Not me. I doubt any of you reading this do either.

    The general manager (+board) should make sure this political, nepotistic, palm crossing crud cannot occur. Seems they have been looking some other way, doesn’t it? Why? They are ALL seriously accountable, since Joe is still on property, correct? For all the screw ups on their beat. There have been plenty of them.

    Again, more of MY opinion:

    This sort of thing is what occurs when there is a UNCHECKED FOR YEARS, playing games general manager (& a handpicked board?) that doesn’t care to do anything in a professional manor, along with that ‘board of buddies’ that bury their head in the sand, allowing Joe UNCHECKED with all of our pocketbooks to use crappy contractors. Joe gets his wonderful paycheck regardless. From all of us owners. Nothing comes out of his pay, does it? We will AGAIN pay over and over to get the job done AGAIN. I guess we just blew $84,000. in 07/08? More bad management and board decisions. Maybe Joe get a commodity rate???????? Jeeze. Maybe it is more personal than that?

    You know…. Joe told me once when i worked here:

    QUOTE: “The SOB’s (his term for all of RML owners, i am sorry to tell you rml owners this.)THEY are gonna pay because he gets 40% and they get 60%” “UNQUOTE”. I suppose he meant that, as he said it to me with a finger pointing at my face and conviction in his voice. Real nice guy, huh. (sarcasm) YES > I WOULD TAKE A POLYGRAPH. That was the day i decided i was quitting my job ~ asap! I figured if the rml owners were called SOB’s then what was myself, a resident, really bad word in his vocabulary, going to be called?

    Is there are a handful of board members that have looked the other way while we continue to pay over and over to do the same job over and over? Seems like it. Look at the job of the pool/jacuzzi that had to be re-done due to the fact that the crew that was hired to do that was fly-by-night, illegals. Much like most everything that occurs here. Both with illegal, non insured, and with unprofessional nepotism that exists here (friends/relatives crossing palms, or political favors?) to provide Joe a dictatorship control.

    Apparently we got what we paid for. We are still paying, aren’t we? Time to make a big change. PERIOD.

Leave a Reply

 

 

 